Products - Conventional transformers Products - HR equivalents
Types and features | Series index | Technical information
  
  
      
  | 
    ||||||||
| HR Ref. | Primary | Sec. | Sec. In | 
         Vo (In=0)  | 
      External protection Fuse | ||||
|---|---|---|---|---|---|---|---|---|---|
| P1 | P2 | S1 | S2 | Is1 | Is2 | 
	     Sec. (F) S1|S2  | 
      
         Prim. (T) 115|220  | 
    ||
| C4821035 | 125 V | 220 V | 4.5 V | 4.5 V | 1000.0 mA | 1000.0 mA | 2x(5.625) V | 2x(1250.0) mA | 125.0 mA | 
| C4821021 | 125 V | 220 V | 6.0 V | 6.0 V | 750.0 mA | 750.0 mA | 2x(7.5) V | 2x(800.0) mA | 125.0 mA | 
| C4821023 | 125 V | 220 V | 7.5 V | 7.5 V | 600.0 mA | 600.0 mA | 2x(9.375) V | 2x(630.0) mA | 125.0 mA | 
| C4821025 | 125 V | 220 V | 9.0 V | 9.0 V | 500.0 mA | 500.0 mA | 2x(11.25) V | 2x(630.0) mA | 125.0 mA | 
| C4821027 | 125 V | 220 V | 12.0 V | 12.0 V | 375.0 mA | 375.0 mA | 2x(15.0) V | 2x(400.0) mA | 125.0 mA | 
| C4821029 | 125 V | 220 V | 15.0 V | 15.0 V | 300.0 mA | 300.0 mA | 2x(18.75) V | 2x(315.0) mA | 125.0 mA | 
| C4821031 | 125 V | 220 V | 18.0 V | 18.0 V | 250.0 mA | 250.0 mA | 2x(22.5) V | 2x(315.0) mA | 125.0 mA | 
| C4821033 | 125 V | 220 V | 24.0 V | 24.0 V | 188.0 mA | 188.0 mA | 2x(30.0) V | 2x(200.0) mA | 125.0 mA | 

Technical characteristics:
- Designed and manufactured according regulations EN61558/6 UL1585/2
 - Double isolation copper wire
 - Two-chamber coil
 - Coated with dried oven varnish class H (180ºC)
 - Vacuum sealed
 - Safety transformer class II / Protection index IP00 (For all models with no load voltage lower than 50V according to EN61558, and to 30V according to UL1585)
 - Thermal class materials B (130ºC/266ºF) or F (155ºC/311ºF) optionally.
 - Ambient temperature of 40ºC/104ºF
 - Primary of 125V-220V
 - Configurations of single secondary, dual secondary and center tapped.
 - Isolation Prim./Sec. superior at 5 MOhm at 500 Vcc
 - Primary dielectric strength / superior secondary at 3 KV, 1min.
 