Products - Ensapsultated transformers    Products - HR equivalents

External protection

E4215

EI 42/14,8

External protection

5.0 VA - 70ºC/B

Logo CE

Simple primary

Simple secondary


E4215

Weight/unit:

200 gr

E4215

Weight/minibox (Units: 5)

1000 gr

E4215

Weight/bigbox (Units: 64)

12800 gr

HR Ref. Primary Sec. Sec. In

Vo

(In=0)

External protection Fuse
P1 P2 S1 S2 Is1 Is2

Sec. (F)

S1

Prim. (T)

P1

E4215064 230 V - 4.5 V - 1111.0 mA - 5.8 V 1250.0 mA 40.0 mA
E4215050 230 V - 6.0 V - 833.0 mA - 7.8 V 1000.0 mA 40.0 mA
E4215052 230 V - 7.5 V - 667.0 mA - 9.7 V 800.0 mA 40.0 mA
E4215054 230 V - 9.0 V - 556.0 mA - 11.7 V 630.0 mA 40.0 mA
E4215056 230 V - 12.0 V - 417.0 mA - 15.6 V 500.0 mA 40.0 mA
E4215058 230 V - 15.0 V - 333.0 mA - 19.5 V 400.0 mA 40.0 mA
E4215060 230 V - 18.0 V - 278.0 mA - 23.4 V 320.0 mA 40.0 mA
E4215062 230 V - 24.0 V - 208.0 mA - 31.2 V 250.0 mA 40.0 mA
E4215

Technical characteristics:

  • Designed and manufactured according regulations EN61558 EN60590 EN60472 UL506 UL1585
  • Two-chamber coil
  • Vacuum sealed
  • Safety transformer class II / Protection index IP00 (For all models with no load voltage lower than 50V according to EN61558, and to 30V according to UL1585)
  • External protection with fuse (See suggested type at table)
  • Self-extinguishing plastic UL94-VO
  • Epoxy resin class F
  • Isolation: Prim./Sec. = 10 MOhm to 500 Vcc - Sec./Sec. = 2 MOhm to 500 Vcc
  • Dielectric strength Prim. / Sec. = 5 kV / 1min.
  • Secondary voltage tolerances 5%
  • Test at 100% of all electrical parameters in production
  • Reliability tests for production batch (life term)
  • Certificates of production test results (under request)
  • Certifications VDE, UL; others certifications under request: CSA, SEMKO